Accurate measurements

   Home  |  Background   |    Why Accufloc  |   Usage  |  Literature  |  Useful links   |  Contact
Useful links  Literature Downloads  

Why is our Streaming Current Meter better than the others?

 

Streaming Current Monitor Comparision

 
AccuFloc
Chemtrac
Milton Roy

Power Supply

230VAC, 50/60 hz (standard),
115VAC,50 hz (option)
115VAC, 50/60 hz (standard),
230VAC,50 hz (option)
115VAC, 50/60 hz (standard)
230VAC, 50 hz (option)

Output Signal

4-20mA (max 500OHM load each) 4-20mA DC 4-20mA (max 500OHM load, isolated)

Meter Readout

Dual 3.5 digit LED
-100 ~ + 100 SCV Scale
Digital LED:
-100 ~ + 100 SCV Scale (or SCD)
Dual Digital Display:
-100 ~ + 100

Communications

RS232 option
RS-485 / MODBUS (isolated) option
  RS-485

Accuracy

0.2% (on an adequately mixed sample)   1% of full scale

Response time

2 seconds   < 5 seconds

Gain Adjustment

Full range External, 5 Pos (1x, 2x, 5x, 10x, 20x) Full range

Zero Adjustment

Full range Full range Full range

Signal Filter

Adjustable low pass 2 second - 1 minute   Adjustable low pass

Probe

Quick Replacement Quick Replacement Probe Cartridge  

Sample Cell

Automatic Jet wash (opt) External Receiver Flow through external type, Manual Jet Wash conn. (std),
Automatic Jet Wash System (opt)

Sample Flow Rate

0.5-20 L/min
(recommended around 5L/min)
0.0189m³/min Standard probe: 2-4 L/min
high flow probe: 4-20 L/min

Sample Flow Sensor

Optional   Optional

Sample Wetted Parts

Stainless Steel, Nylon, Epoxy Delrin, Nylon, Neoprene Viton, PVC, Stainless PVC, Delrin, PTFE, Silver

Sample Connections

In: 1/2" Out: 3/4" BSP 3/4" O.D BAR type (inflow)
1" O.D (outflow)
Barb Type 1/2" ID tube (std)
Barb Type 1" ID tube (high flow)

Calibration

One step quick calibration    

Alarm

2x Adjustable setpoint
Fully adjustable span and zero 1x Fault alarm (SPST 5A 230 VAC)
Full Scale All Range Band type: Deviation from set point
Relays: SPDT, 2 amps at 115/230 VAC

Ambient Temperature

-25°C ~ 50°C -14.2°C ~ 34.7°C 0°C ~ 50°C

Enclosure

316 Stainless Steel, IP65 NEMA 4X, Polycarbonate NEMA 4X, 316 Stainless Steel

Control Funcitons

PID (opt)
Manual tune
  Single loop Proportionla + Integral + Derivative (PID) control; Continuous auto tune; Microproccessor based with self diagnostics; Automatic & Manual mode selectable

Weight

12 kg Sensor, 5 kg transmitter 4.535kgs(sesnor), 6.349kgs(transmitter) 24 lbs. (=10.89kgs)

back to top

Contact us: sales@accufloc.com
Ph: +64 9 579 1888   Fax: +64 9 579 1888
Phone Free Within New Zealand: 0800 50 55 66  
copyright © ACCUFLOC 2004